Product Code : ECON-F
Brand Name : MRM PROCOM PVT. LTD
Product Description

Manual Controllers

  • ECON- F/P is an Engine Control / Protection Unit for engines used for NON DG applications.
  • The controller can measure signals from either MPU or charging alternator to calculate RPM.
  • ECON provide choice of Variety of sensor selection from predefined section chart
  • In critical operation it is possible to disable or debar tripping of engine via an external digital input.
  • 128x64 pixel graphical display enhance convenience in configuration of controller.

Protection, Supervision Salient Features:

Protection

  • Oil Pressure
  • HWT
  • RWL
  • Emergency
  • Low Fuel
  • Charging Alternator Fail/V-Belt
  • Choice of selective sensor measurement display

Display and Measurement

  • Battery Voltage
  • Engine Run Hour
  • RPM
  • Oil Pressure in KG/cm2
  • Water Temp in degree centigrade
  • Fuel Level in %
  • Programmed settings
  • Service Hour

Digital Output

Seven digital output (Six negative and one positive) are available, four output contacts programmable.

  • Crank (Battery Negative)
  • Annunciation 2 (Battery Negative)
  • Charging Alternator (Battery positive)
  • Annunciation 3 (Battery Negative)
  • Solenoid (Battery Negative)
  • Annunciation 4 (Battery Negative)
  • Annunciation 1 (Battery Negative)

Digital Input

ECON can measure / detect three Analog, seven digital and one pulse input terminal. These inputs are as mentioned below.

  • LOP Sensor: Resistive sensor can be connected to LUBE OIL PRESSURE terminal(2). Pre Programmed sensor value (Listed in TABLE 5.1) can be assigned to LOP input
  • WT Sensor: Resistive sensor can be connected to WATER TEMPERATURE terminal(3). Pre Programmed sensor value (Listed in TABLE 5.1) can be assigned to WT input
  • Fuel Sensor: Resistive sensor can be connected to FUEL SENSOR terminal (4). Pre Programmed sensor value (Listed in TABLE 5.1) can be assigned to fuel input
  • LOP Switch: Oil pressure switch can be connected to LOP switch terminal (6) . The input is activated on connection of DC negative at terminal no. 6. On activation stop command is issued to the engine and the fault is indicated on front LED.
  • WT Switch: Water Temperature switch can be connected to HWT switch terminal (7). The input is activated on connection of DC negative at terminal no. 7. On activation stop command is issued to the engine and the fault is indicated on front LED
  • Fuel Switch: Fuel level switch can be connected to fuel level switch terminal (8). The input is activated on connection of DC negative at terminal no. 8. On activation stop command is issued to the engine and the fault is indicated on front LED
  • Emergency Off: The input is activated on connection of DC negative at terminal no. 9. On activation stop command is issued to the engine and the fault is indicated on front LED
  • Protection Debar: The input is activated on connection of DC negative at terminal no. 9. On activation ECON disable trip function on all the faults.
  • Remote Start: ECON issues start command to engine On receipt of DC negative at remote start terminal
  • Remote Stop: ECON issues stop command to engine On receipt of DC negative at remote stop terminal

Indication

Listed below are the two LED indication available on front of ECON-F/P

  • Warning : Blinks in case of sensor open or on low fuel warning
  • Fault : Blinks on any fault which results in engine shutdown

Setting Procedure / Menu
ECON is user / site configurable. User can view all parameters, fault history, events no. of start stop
and can also edit, system parameter (password protected), engine / generator parameter, annunciation
setting, clock and password.

Following is the sequential procedure to edit. view all the menu and sub-menus

Press "R" & "Enter" switch simultaneously.
The LCD shall display, "System Parameter"

A. System Parameter

  • System parameter are password protected.
  • To enter "system parameter" press "Enter".
  • ECON will request for password, LCD will display "Enter Password"
  • System parameter can be edited by entering correct password or else can be viewed by entering "0" as password.

B. Engine / Generator Parameter

  • To go to next menu after system parameter, press "Increment".
  • The LCD shall display "Generator Parameter".
  • Generator parameter can modified / viewed by pressing "Enter".
    for setting details pls refer table 5.1)

C. Annunciation Setting
       To go to next menu after generator parameter, press “Increment”.
       The LCD shall display “annunciation setting”.
       Annunciation settings can modified / viewed by pressing “Enter”.
       (for setting details pls refer table 5.1)

D. Display History

  • To go to next menu after annunciation press "Increment".
  • The LCD shall display "Display History".
  • Trip record / history can be viewed by pressing "Enter".
  • ECON keep a record of last 32 tripping with date and time stamp.
  • Tripping records are updated on first in first out basis

E. Display Event

  • To go to next menu after history press "Increment".
  • The LCD shall display "Display Event".
  • Generator parameter can be modified / viewed by pressing "Enter".
  • ECON keep a record of last 32 event with date and time stamp.
  • Event record is updated on first in first out basis.

F. Display Start Stop

  • To go to next menu after event press "Increment".
  • The LCD shall display "Display Start / Stop".
  • Generator parameter can modified / viewed by pressing "Enter".
  • ECON keep a record of last 100 start and stop event with date and time stamp.
  • Start/ stop record is updated on first in first out basis.

G. Reset Service Alarm

  • To go to next menu after annunciation press "Increment".
  • The LCD shall display "Reset Service Alarm".
  • Service due hour can be reset by pressing start button after entering in to this menu.

H. Adjust Clock

  • To go to next menu after annunciation press "Increment".
  • The LCD shall display "Adjust Clock".
  • Time can be modified / viewed by pressing "Enter".

I. Reset Password

  • To go to next menu after annunciation press "Increment".
  • The LCD shall display "Reset Password".
  • Password can be modified by pressing "Enter"
  • ECON will request for the present password, after feeding correct password change password will be requested and the password will be replaced by new password on pressing start button..

Technical Specification:

AC voltage withstand

330 VAC, Continuously, (Phase to neutral)

Frequency Range

40-70 Hz

Measurement Accuracy

Voltage & Current: + 2%

Frequency: + 0. 05 Hz.

Surge 1.2/50Usec

2.5KV

Auxiliary Voltage

8-35V/DC OR 50-300 V AC/DC

Contact Rating

230 VAC, 5A


Download PDF File

MRM PROCOM PVT. LTD.

Contact Us

( *represents compulsory fields )

Tips on getting accurate quotes. Please include product name, order quantity, usage, special requests if any in your inquiry.



Contact Details
  • MRM PROCOM PVT. LTD.
  • Plot No. 20-21, Sector 59, Phase-2, Faridabad - 121004, Haryana, India
  • Send Inquiry      Call Me Free Offline Send SMS
  • Mr. Pankaj Gupta (Director)
MRM PROCOM PVT. LTD. All Rights Reserved.