Cookie Img
Send Inquiry Send SMS    Call Me Free Offline
Home » Products » Manual Controllers » Manual Controllers

Manual Controllers

Manual Controllers
Manual Controllers
Product Code : DES-P
Brand Name : MRM PROCOM PVT. LTD
Product Description

Manual Controllers

Protection, Supervision Salient features
  • Oil Pressure
  • Low Fuel
  • HWT
  • Charging Alternator Fail/V-Belt
  • RWL
  • Choice of selective sensor measurement
  • Emergency display
  • Choice of selective sensor measurement display
Measurement & Display
DES-P equipped with LCD display and displays
  • Battery Voltage
  • Water Temp in degree centigrade
  • Generator Run Hour
  • Fuel Level in %
  • RPM
  • Programmed settings
  • Oil Pressure in KG/cm2

Service Hour


Normally the display auto scrolls and displays a set of parameter for 10 seconds, but any time the Next key (^) can be pressed to select the next parameter window.

Parameter Mode

Display

Explanation of parameter

Factory Setting

Setting Range

Engine Max RPM

Max. permissible RPM, above this the RPM is treated unhealthy & the Generator is stopped.

1650

300-3000

Engine O/RPM Delay

The time for which the Generator RPM should, continuously be unhealthy to generate a fault condition

10Sec.

1-999 Sec.

Engine Vbelt RPM

Max. permissible Vbelt RPM, above this the RPM is treated unhealthy & the Generator is stopped.

300

300-600

V belt Delay

The time for which the Vbelt RPM should, continuously be unhealthy to generate a fault Condition

10Sec

1-999 Sec.

Available Sensor

This select the installed sensors in the Gensets. The display shall only display the parameters for the sensor installed and uninstalled sensor data shall not be displayed. The protection for the function with no measurement sensor installed shall be through switch. Eg. If Oil pressure sensor is not installed the unit shall provide protection for LLOP through oil pressure switch and not through the oil pressure sensor (linear measurement)

All sensors

All sensors,

Fuel Level in %

Level of fuel at which the Engine shall shut down

11%

10-100%

Low Lube Pressure

Level of LLOP at which the Engine shall shut down

1.0 Kg/Cm2

0-8.5 Kg/Cm2

High Water Temp

Temperature of water at which the Engine shall shut down

95

0-150 Degree centigrade

Sensor Type

Select sensor as in accordance with engine

A

A,B

 

Specifications

Surge 1.2/50Usec

2.5KV

Battery Voltage

Suitable for 12V/24 VDC System

Min. voltage to power on

9V

Min Running Voltage after Power on

4V

Max. Battery Voltage

35V

DC Interruption time

1 Sec.

Digital Output

+ 12V

Cut out Dimensions

92mm X 92mm

Depth

120mm

Digital Input Level battery + Ve

Battery -Ve except Charging Alt, which is

 Download PDF File


MRM PROCOM PVT. LTD.

Contact Us

( *represents compulsory fields )

Tips on getting accurate quotes. Please include product name, order quantity, usage, special requests if any in your inquiry.



Contact Details
  • MRM PROCOM PVT. LTD.
  • Plot No. 20-21, Sector 59, Phase-2, Faridabad - 121004, Haryana, India